Quick answer
Journeyman electrician exams in Oregon and Washington test electrical theory, calculations and the National Electrical Code. Washington's L&I exams are open book with approved references, and you need 70% on each section. Expect Ohm's law, overcurrent protection, dwelling requirements, working space, box fill and grounding.
Practice only. Not an official test.
These are original practice questions written by PITHE Digital Group for study purposes, based on public laws, codes and agency guidance. They are not real or past exam questions, and this page is not affiliated with, endorsed by or sponsored by the Oregon Building Codes Division, Washington Labor & Industries, NFPA or PSI or any testing company. A score here does not predict your real exam result and does not give you any license, permit, card or certificate.
Laws, codes and fees change, and mistakes are possible. Always confirm with the official agency and your approved course materials. This is general educational information, not legal or professional advice. Read the full disclaimer.
Exam facts are from public agency sources as of November 7, 2026. Confirm current details with the official agency before you schedule.
Oregon licenses electricians through the Building Codes Division, and Washington through Labor and Industries. Both build on the National Electrical Code. Use this practice test to sharpen your theory, math and code lookups before your journeyman or contractor exam.
How it works: tap an answer to see if you got it right, why, and the law or code it comes from. Your progress saves on this device only, so you can bookmark the page and pick up later. No signup, no card.
Jump to: Electrical theory and math · Conductors and overcurrent protection · Dwelling unit requirements · Working space, boxes and raceways · Grounding and bonding · Oregon and Washington licensing
Electrical theory and math
Practice question 1 · Electrical theory and math
A 120-volt circuit has a resistance of 10 ohms. What is the current?
Answer: A. 12 amps Ohm's law: I = E / R = 120 / 10 = 12 amps.Source: Ohm's law
Practice question 2 · Electrical theory and math
A 240-volt load draws 20 amps. How many watts is that?
Answer: D. 4,800 watts Power = volts x amps = 240 x 20 = 4,800 watts.Source: Power formula (P = E x I)
Practice question 3 · Electrical theory and math
A 1,500-watt space heater runs on 120 volts. About how many amps does it draw?
Answer: A. 12.5 amps I = P / E = 1,500 / 120 = 12.5 amps.Source: Power formula
Practice question 4 · Electrical theory and math
Three 10-ohm resistors are wired in series. What is the total resistance?
Answer: A. 30 ohms In series, resistances add: 10 + 10 + 10 = 30 ohms.Source: Series circuit rules
Practice question 5 · Electrical theory and math
Two 10-ohm resistors are wired in parallel. What is the total resistance?
Answer: B. 5 ohms Equal resistors in parallel: R / number of resistors = 10 / 2 = 5 ohms.Source: Parallel circuit rules
Practice question 6 · Electrical theory and math
What multiplier is used for three-phase power calculations?
Answer: A. 1.732 Three-phase power = volts x amps x 1.732 (the square root of 3), times power factor.Source: Three-phase power formula
Practice question 7 · Electrical theory and math
About how many amps does a 75 kVA three-phase transformer deliver at 208 volts?
Answer: B. 208 amps I = 75,000 / (208 x 1.732) = about 208 amps.Source: Three-phase current formula
Practice question 8 · Electrical theory and math
In a perfectly balanced three-phase wye system, what current flows on the neutral?
Answer: B. Zero (in theory) Balanced phase currents cancel on the neutral. Real systems with nonlinear loads can still carry neutral current.Source: Three-phase circuit theory
Conductors and overcurrent protection
Practice question 9 · Conductors and overcurrent protection
Unless a specific exception applies, what is the maximum overcurrent protection for 14 AWG copper?
Answer: C. 15 amps The small conductor rule limits 14 AWG copper to 15A, 12 AWG to 20A and 10 AWG to 30A.Source: NEC 240.4(D)
Practice question 10 · Conductors and overcurrent protection
What is the maximum overcurrent protection for 12 AWG copper under the small conductor rule?
Answer: B. 20 amps 12 AWG copper is limited to 20 amps.Source: NEC 240.4(D)
Practice question 11 · Conductors and overcurrent protection
A continuous load draws 16 amps. What is the minimum standard breaker size?
Answer: B. 20 amps Overcurrent devices for continuous loads are sized at 125%: 16 x 1.25 = 20 amps.Source: NEC 210.20(A)
Practice question 12 · Conductors and overcurrent protection
How long must a load run to be called "continuous"?
Answer: C. 3 hours or more A continuous load is one where maximum current is expected for 3 hours or more.Source: NEC Article 100, definition of Continuous Load
Practice question 13 · Conductors and overcurrent protection
Which colors identify a grounded (neutral) conductor?
Answer: B. White or gray Grounded conductors are white or gray (or have three white stripes).Source: NEC 200.6
Practice question 14 · Conductors and overcurrent protection
Which can identify an equipment grounding conductor?
Answer: B. Bare, green, or green with yellow stripes Equipment grounding conductors are bare, covered or insulated green, or green with yellow stripes.Source: NEC 250.119
Practice question 15 · Conductors and overcurrent protection
For motor branch-circuit conductor sizing, what current value do you normally use?
Answer: A. The full-load current from the NEC motor tables Conductor and overcurrent sizing generally uses the table full-load current, not the nameplate.Source: NEC 430.6(A)(1)
Practice question 16 · Conductors and overcurrent protection
What is required for a multiwire branch circuit?
Answer: D. A means to simultaneously disconnect all ungrounded conductors at the point of origin Handle ties or a multi-pole breaker make sure all hots open together.Source: NEC 210.4(B)
Dwelling unit requirements
Practice question 17 · Dwelling unit requirements
In a dwelling, where is GFCI protection required for 125-volt receptacles?
Answer: C. Bathrooms, garages, outdoors, kitchens, and within 6 feet of sinks, among others Dwelling GFCI locations include bathrooms, garages, outdoors, crawl spaces, unfinished basements, kitchens and areas near sinks.Source: NEC 210.8(A)
Practice question 18 · Dwelling unit requirements
Along a dwelling wall, receptacles are placed so no point along the floor line is more than how far from a receptacle?
Answer: D. 6 feet The 6-foot rule means receptacles end up roughly every 12 feet.Source: NEC 210.52(A)(1)
Practice question 19 · Dwelling unit requirements
How wide must a wall space be to require a receptacle in a dwelling living area?
Answer: C. 2 feet or more Any wall space 2 feet or more wide needs a receptacle.Source: NEC 210.52(A)(2)
Practice question 20 · Dwelling unit requirements
Kitchen wall countertop receptacles are placed so no point along the wall line is more than how far from a receptacle?
Answer: B. 24 inches No point along the countertop wall line may be more than 24 inches from a receptacle.Source: NEC 210.52(C)(1)
Practice question 21 · Dwelling unit requirements
How many 20-amp small-appliance branch circuits are required for a dwelling kitchen?
Answer: A. At least two At least two 20-amp small-appliance branch circuits serve the kitchen, pantry, dining and similar areas.Source: NEC 210.11(C)(1)
Practice question 22 · Dwelling unit requirements
What branch circuit is required for dwelling bathroom receptacles?
Answer: D. At least one 20-amp circuit At least one 20-amp branch circuit supplies the bathroom receptacle outlets.Source: NEC 210.11(C)(3)
Practice question 23 · Dwelling unit requirements
A bathroom receptacle must be within how far of the outside edge of each basin?
Answer: B. 3 feet At least one receptacle within 3 feet of each basin's outside edge.Source: NEC 210.52(D)
Practice question 24 · Dwelling unit requirements
What protection is required for most 120-volt, 15- and 20-amp branch circuits supplying outlets in dwelling bedrooms and living rooms?
Answer: B. AFCI protection Arc-fault protection is required in bedrooms, living rooms, kitchens and many other dwelling areas.Source: NEC 210.12
Practice question 25 · Dwelling unit requirements
What type of receptacle is required in most areas of a dwelling?
Answer: A. Tamper-resistant receptacles Tamper-resistant receptacles help keep kids from inserting objects.Source: NEC 406.12
Practice question 26 · Dwelling unit requirements
How close to a box must NM cable (Romex) be secured?
Answer: B. Within 12 inches, and supported at intervals not over 4 1/2 feet NM cable is secured within 12 inches of boxes and every 4 1/2 feet.Source: NEC 334.30
Practice question 27 · Dwelling unit requirements
Outdoor receptacles: how many are required at a one-family dwelling at grade level?
Answer: B. At least one at the front and one at the back At least one receptacle readily accessible from grade, front and back, not more than 6 1/2 feet above grade.Source: NEC 210.52(E)(1)
Working space, boxes and raceways
Practice question 28 · Working space, boxes and raceways
What is the minimum width of working space in front of a panelboard?
Answer: A. 30 inches, or the width of the equipment if wider Working space is at least 30 inches wide or the width of the equipment, whichever is greater.Source: NEC 110.26(A)(2)
Practice question 29 · Working space, boxes and raceways
For equipment 0 to 150 volts to ground (Condition 1), what is the minimum depth of working space?
Answer: C. 3 feet Table 110.26(A)(1) requires 3 feet for 0 to 150 volts to ground in Condition 1.Source: NEC Table 110.26(A)(1)
Practice question 30 · Working space, boxes and raceways
What is the minimum headroom for working space at service equipment and panelboards?
Answer: C. 6 1/2 feet Headroom is generally 6 1/2 feet or the height of the equipment, whichever is greater.Source: NEC 110.26(A)(3)
Practice question 31 · Working space, boxes and raceways
In a box fill calculation, how much volume is counted for each 14 AWG conductor?
Answer: D. 2.00 cubic inches 14 AWG = 2.00 cu in, 12 AWG = 2.25 cu in, 10 AWG = 2.50 cu in.Source: NEC Table 314.16(B)
Practice question 32 · Working space, boxes and raceways
How much volume is counted for each 12 AWG conductor in a box fill calculation?
Answer: D. 2.25 cubic inches 12 AWG conductors count 2.25 cubic inches each.Source: NEC Table 314.16(B)
Practice question 33 · Working space, boxes and raceways
What is the maximum conduit fill for three or more conductors?
Answer: D. 40% Over two conductors, fill is limited to 40% of the conduit's cross-section.Source: NEC Chapter 9, Table 1
Practice question 34 · Working space, boxes and raceways
Can flexible cord be used as a substitute for fixed wiring of a structure?
Answer: A. No Flexible cords and cables may not be used as a substitute for the fixed wiring of a structure.Source: NEC 400.12
Grounding and bonding
Practice question 35 · Grounding and bonding
What is bonding?
Answer: A. Connecting metal parts together to make an electrically conductive path Bonding ties metal parts together so fault current has a low-impedance path and parts stay at the same potential.Source: NEC Article 100, definition of Bonded (Bonding)
Practice question 36 · Grounding and bonding
What is the minimum length of a rod or pipe grounding electrode?
Answer: B. 8 feet Rod and pipe electrodes must be at least 8 feet long.Source: NEC 250.52(A)(5)
Practice question 37 · Grounding and bonding
A single rod electrode does not measure 25 ohms or less to earth. What is required?
Answer: B. A supplemental electrode A single rod must be supplemented unless it has 25 ohms or less resistance to earth.Source: NEC 250.53(A)(2)
Practice question 38 · Grounding and bonding
Where is the main bonding jumper installed?
Answer: C. At the service, connecting the equipment grounding conductors to the grounded conductor Neutral and ground are bonded at the service, not downstream at subpanels.Source: NEC 250.24 and 250.28
Practice question 39 · Grounding and bonding
What is the recommended maximum voltage drop for a branch circuit in the NEC informational notes?
Answer: B. 3% The informational notes suggest 3% for branch circuits and 5% total for feeder plus branch circuit.Source: NEC 210.19 Informational Note
Practice question 40 · Grounding and bonding
A receptacle outdoors in a wet location must be what type?
Answer: D. Listed weather-resistant, with an in-use cover where required Wet and damp location receptacles must be weather-resistant, and many need extra-duty in-use covers.Source: NEC 406.9
Oregon and Washington licensing
Practice question 41 · Oregon and Washington licensing
Which agency handles electrical licensing in Washington?
Answer: A. Labor and Industries (L&I) Washington L&I issues electrical contractor and electrician licenses and runs the exams with PSI.Source: Washington State Department of Labor & Industries
Practice question 42 · Oregon and Washington licensing
Which agency handles electrical licensing in Oregon?
Answer: B. The Building Codes Division (Electrical and Elevator Board) Oregon BCD and its Electrical and Elevator Board license electricians. Electrical contractors also need a CCB license.Source: Oregon Building Codes Division
Practice question 43 · Oregon and Washington licensing
Are the Washington electrical license exams open book?
Answer: A. Yes, with approved references such as the NEC, RCW 19.28 and WAC 296-46B L&I lists allowed references for the open-book exam. Practice finding answers in the code fast.Source: Washington L&I, Electrical examination
Practice question 44 · Oregon and Washington licensing
What score is needed on each section of the Washington electrical exam?
Answer: C. 70% You must score at least 70% on each section.Source: Washington L&I, Electrical examination
Practice score only. This is not an official result and does not predict how you will do on the real exam.
Going out on your own? You will need an electrical contractor license, a CCB license in Oregon, and customers. We list electricians free and build websites that turn searches into service calls.
How to pass: study tips that work
- Tab your NEC by article: 100 definitions, 110 working space, 210 branch circuits, 240 overcurrent, 250 grounding, 314 boxes, Chapter 9 tables.
- Do math daily: Ohm's law, power, three-phase (x 1.732) and 125% continuous loads.
- Learn the index. Fast lookups win open-book exams.
- Use the edition your state adopted.
Official sources to study from
Use the official materials and approved courses as your real guide. These links go to the agencies, not to us.
See a mistake or an outdated rule? Tell us and we will check it against the official source and fix it.
More free practice tests
Common questions
Is the Washington electrician exam open book?
Yes. Washington L&I allows approved references such as the NEC, RCW 19.28 and WAC 296-46B, and you need 70% on each section.
Who licenses electricians in Oregon?
The Oregon Building Codes Division and its Electrical and Elevator Board. Electrical contractors also need a CCB license.
Which NEC edition applies?
States adopt NEC editions on their own schedule with amendments. Check the current Oregon Electrical Specialty Code or Washington's adopted edition before your exam.
Are these real Electrical (NEC) exam questions?
No. They are original practice questions written by PITHE Digital Group from public laws, codes and agency guidance. They are not real or past exam questions, and we are not affiliated with the Oregon Building Codes Division, Washington Labor & Industries, NFPA or PSI or any testing company.
Does passing this Electrical (NEC) practice test give me a license or certificate?
No. This free practice test is for study only. You must complete the official requirements and pass the official exam through the agency or its approved provider.
Is this practice test free?
Yes. It is free with no signup. Your progress saves only on your device.